- Ensure adequate surface prep: remove scale, paint, and oil
- Verify magnetization direction covers the flaw orientation of interest
- Keep particle bath agitated — settlement causes weak indications
- If indications look fuzzy, reduce background by improving surface contrast
- Demagnetize parts when required before handing them back
Download the full NDT Field Checklist here (DOWNLOAD CHECKLIST)